πŸ‘‰ How I answer [Valve Authority] in Control Valves


πŸ‘‰ " Three Times Better (Engineer) "

The 3 Things You will learn today are as follows.

➜ One Engineering Learning

Why only Control Valve are less than Line Size and not On-Off valves.

➜ One Engineering Question

What will you do if control valve noise is 90 DBA.

➜ One Career Tip from Top Professionals

If you choose the difficult path then life becomes easy.


Before we start,

If you want to Master and perform "Live" Control Valve Sizing.

Then on 27th and 28th June

We are having a 2 day Valve Sizing Workshop.

For Free.

Join the Whatsapp Community to get the Zoom Link.

Incase, you miss you get the recordings as well.

Lets get to today knowledge sharing email.


#1 -Engineering Learning

Let me ask you a question.

It often appears in tough engineering interviews.

Places like Exxon, Shell, or Qatar Energy.

Why is a control valve smaller than the line?
Is it simply to save costs?

If you answered YES.

Then that answer is entirely incorrect.

Why?


The On-Off Valve Comparison

Let us apply that exact same logic.

We could shrink on-off valves too.

It would definitely save project costs.

But we never do that.

Why?

because Making a control valve smaller... Is done for a completely different reason.

The Science of Pressure Drop

The real answer is pressure drop.

Look at any system with a control valve.

The pressure drop splits into two parts.

  • First, across the control valve.
  • Second, across the surrounding piping.

The ratio between these two parts... Is formally known as Valve Authority.


Why Authority Matters

More pressure drop across the valve?

Means the valve holds more "Authority".

More DP equals better controllability.

So you might ask me:
Why not make the valve as small as possible?

If we make it too small...

System stress becomes dangerously high.

That results in a poorly designed system.

We need to maintain a strict balance.

  • ➜ Pressure across the valve itself.
  • ➜ Pressure across the piping components.

This Valve Authority is critical.

It dictates your valve selection and valve characteristics.


Master Control Valve Sizing

This concept is too deep for one email.

But we cover this in-depth in the 2 day workshop.​

Are you an engineering nerd like me?

Want to design bulletproof control valves?

So nobody can ever question your work?

  1. I am hosting a 2-day workshop on Control Valves.
  2. It is completely free to attend.
  3. Dates: 27th and 28th June.

We skip the basic textbook theory.

We dive right into real valve sizing engineering.

Hop into this WhatsApp notification group.

➜ [Click here to Join the Group]

I will share the Zoom link there.

PS: What if you miss a session?

You will get the full recordings.

But only if you join the WhatsApp group.​

PS: The reason for Whatsapp group is to send the zoom link to only those interested not email to all the 10,000+ of engineers in this email learning community


#2- Engineering Question

Question of this Week

If you control valve noise is 90 DBA and you are working on a UK project.

What will you do ?

Option 1 : Go for Source (Noise) Treatment

Option 2 : Go for Path (Noise) Treatment

Option 3 : Ask Client.

Option 4 : No Action.


#3 -Career Tip

When something sounds technical, I get excited.

Because the more technical something is, there’s nearly always low competition.

And you have the opporunity to shine.

So do the hardwork and learn things others are scared of.

Proud of You !

Keep learning and Growing to be World Class Engineer!!


How was today's learning

  • Highly Valuable : Reply 1
  • Somewhat Valuable : Reply 2
  • Needs Improvement : Reply 3

I see each feedback reply as a gift.


Until next week,

Happy Learning & Keep Smiling.

Asad Shaikh

Your Instrumentation Friend!! 😊

See you next week!

PS: If you would like to Join 2 Day Workshop Control Valve Sizing to master Caviation , Flashing and High Noise then join the Whatsapp Community here.

LBS Road , Mumbai, Maharashtra 400086
​Unsubscribe Β· Preferences​

LBS Road , Mumbai, Maharashtra 400086
​Unsubscribe Β· Preferences​

Asad Shaikh

I'm a youtuber and educator who loves to talk about Instrumentation and Control Engineering. Subscribe and join over 10,000+ newsletter readers every week!

Read more from Asad Shaikh
Fire and Gas Wiring

The 3 Things You will learn today are as follows. What are the Wiring Classes (A,B,X) defined in NFPA 72 The World's top Fire & Gas Standard. Habits that make you world class. The Brain [🧠] Last week, We learnt about Addressable V/S Conventional F&G Communication System. Nearly 4,000+ People shared that they found it valuable. So thought to go a bit in-depth On how to Wire them. To Clear the Confusion. The wiring methods that you will learn today (As per NFPA 72) Class A Class B Class X Can...

person holding tool during daytime

πŸ‘‰ " Three Times Better (Engineer) " The 3 Things You will learn are as follows. πŸ‘‰ One Engineering Question πŸ‘‰ One Engineering Standard πŸ‘‰ One Career Tip from Top Professionals Before we start : If you would like to access PDF of the "Instrumentation Engineers guide to Orifice Flowmeter Sizing" then reply "Orifice Sizing PDF" And I will send it to you. #1 -Engineering Question πŸ‘‰ "Hi Asad,How do we perform Orifice Plate Sizing ? I am confused since there are multiple parameters - Is there a Step...

Hey there, What if one intense 60-minute crash course on control valves could change your career forever? Let me share a story, That still gives me the insane energy to teach control valve technology despite my busy schedule and commitments. The Desperate Call On Saturday 30th August. An engineer called me in a panic. he'd aced his first interview round but fell flat on control valves. He didn't even know what a flange rating was. Let alone how to calculate it. Below is a picture of his...